UNIGLAS | ECONTROL
Product Variants
Area of Application
Vertical and horizontal glazing in surface construction, installation preferably in mullion–transom constructions, post width 60 mm.
Geometry
Rectangular and similar formats, models as in catalogue.
Light Transmission
Controllable in the range TL 50 % to TL 15 % in accordance with DIN EN 410.
Heat Transfer
Ug = 1.1 W/m²K (standard) according to DIN EN 673
Solar Heat Gain Coefficient - double insulation in accordance with DIN EN 410
g = 38 % at TL = 50 % g = 12 % at TL = 15 %.
Dynamic Selectivity
As the sun control can be varied with UNIGLAS® | ECONTROL, the performance capability is calculated by comparison of the light transmission in a brightened state with the energy transmission in a coloured state.
The measure for this is the dynamic selectivity S*= TL(max) / g(min). UNIGLAS® | ECONTROL thus achieves values over 4.
Energy Consumption
UNIGLAS® | ECONTROL requires electrical energy only for the alteration of the transmission: less than 0.5 Wh/m² for the change from light to dark. Adjustment is carried out using the control unit contained in the scope of supply, with a low voltage of ≤ 5 Volt. The control unit is supplied with 24V direct voltage.
Glass Dimensions
Shorter edge 40 - 120 cm, longer edge 40 - 200 cm; 120 x 220 cm maximum, 40 x 40 cm minimum, smaller or larger dimensions:
on enquiry
Standard Construction
Standard insulation glass construction (29 mm), consisting of electrochromic compound with heat-strengthened glass (HSG) (9 mm) outside, space between panes (16 mm), heat protection coated pane of float glass (4 mm) inside.
Noise Insulation
The standard insulation structure with 4 mm inner pane and argon filling achieves the rated noise insulation level of Rw 35 dB (in accordance with DIN EN ISO 717-1).
Safety
Insulation glass units with laminated sheet glass; special structures with ESG: on enquiry.